Critical

Siemens Mendix Studio Pro

All CISA Advisories

Overview

Siemens Mendix Studio Pro has a significant security vulnerability that affects multiple versions of the software, specifically those before version 11.12. This flaw allows attackers to execute arbitrary code by tricking users into opening malicious project files during the build process. The affected versions include Mendix Studio Pro 10.11 through 10.24, as well as 11.0 through 11.9. Siemens has released updates to address this issue, urging users to upgrade to version 10.24.21 or later, or version 11.6.7 or later. This vulnerability poses a serious risk, particularly in critical sectors like manufacturing and energy, making timely updates essential to protect user systems from potential exploits.

Key Takeaways

  • Affected Systems: Affected products include Mendix Studio Pro versions 10.11 to 10.24 (all versions), and 11.0 to 11.9 (all versions).
  • Action Required: Users should update to Mendix Studio Pro version 10.
  • Timeline: Disclosed on June 30, 2026

Original Article Summary

View CSAF Summary Mendix Studio Pro versions before V11.12 are affected by a file parsing vulnerability that could be triggered when the application reads specially crafted malicious project during the build pipeline. This could allow an attacker to execute arbitrary code in the context of that user. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Mendix Studio Pro are affected: Mendix Studio Pro 10.11 vers:all/* Mendix Studio Pro 10.12 vers:all/* Mendix Studio Pro 10.13 vers:all/* Mendix Studio Pro 10.14 vers:all/* Mendix Studio Pro 10.15 vers:all/* Mendix Studio Pro 10.16 vers:all/* Mendix Studio Pro 10.17 vers:all/* Mendix Studio Pro 10.18 vers:all/* Mendix Studio Pro 10.19 vers:all/* Mendix Studio Pro 10.20 vers:all/* Mendix Studio Pro 10.21 vers:all/* Mendix Studio Pro 10.22 vers:all/* Mendix Studio Pro 10.23 vers:all/* Mendix Studio Pro 10.24 vers:intdot/<10.24.21 Mendix Studio Pro 11.0 vers:all/* Mendix Studio Pro 11.1 vers:all/* Mendix Studio Pro 11.10 vers:all/* Mendix Studio Pro 11.11 vers:all/* Mendix Studio Pro 11.2 vers:all/* Mendix Studio Pro 11.3 vers:all/* Mendix Studio Pro 11.4 vers:all/* Mendix Studio Pro 11.5 vers:all/* Mendix Studio Pro 11.6 vers:intdot/<11.6.7 Mendix Studio Pro 11.7 vers:all/* Mendix Studio Pro 11.8 vers:all/* Mendix Studio Pro 11.9 vers:all/* CVSS Vendor Equipment Vulnerabilities v3 5.4 Siemens Siemens Mendix Studio Pro Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-48192 Affected versions of Mendix Studio Pro do not properly validate or sanitize project files processed during the build pipeline. This could allow an attacker who tricks a user into opening and running a specially crafted malicious project locally on their system to execute arbitrary code in the context of that user. View CVE Details Affected Products Siemens Mendix Studio Pro Vendor: Siemens Product Version: Mendix Studio Pro 10.11, Mendix Studio Pro 10.12, Mendix Studio Pro 10.13, Mendix Studio Pro 10.14, Mendix Studio Pro 10.15, Mendix Studio Pro 10.16, Mendix Studio Pro 10.17, Mendix Studio Pro 10.18, Mendix Studio Pro 10.19, Mendix Studio Pro 10.20, Mendix Studio Pro 10.21, Mendix Studio Pro 10.22, Mendix Studio Pro 10.23, Mendix Studio Pro 10.24 < V10.24.21, Mendix Studio Pro 11.0, Mendix Studio Pro 11.1, Mendix Studio Pro 11.10, Mendix Studio Pro 11.11, Mendix Studio Pro 11.2, Mendix Studio Pro 11.3, Mendix Studio Pro 11.4, Mendix Studio Pro 11.5, Mendix Studio Pro 11.6 < V11.6.7, Mendix Studio Pro 11.7, Mendix Studio Pro 11.8, Mendix Studio Pro 11.9 Product Status: known_affected Remediations No fix planned Currently no fix is planned Vendor fix Update to V10.24.21 or later version https://docs.mendix.com/releasenotes/studio-pro/10.24/ Vendor fix Update to V11.6.7 or later version https://docs.mendix.com/releasenotes/studio-pro/11.6/ Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.4 MEDIUM CVSS:3.1/AV:N/AC:H/PR:H/UI:R/S:C/C:N/I:H/A:N Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-779310 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-06-30 Date Revision Summary 2026-06-30 1 Publication Date 2026-07-07 2 Initial CISA Republication of Siemens ProductCERT SSA-779310 advisory Legal Notice and Terms of Use

Impact

Affected products include Mendix Studio Pro versions 10.11 to 10.24 (all versions), and 11.0 to 11.9 (all versions).

Exploitation Status

No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.

Timeline

Disclosed on June 30, 2026

Remediation

Users should update to Mendix Studio Pro version 10.24.21 or later, or version 11.6.7 or later to mitigate the vulnerability.

Additional Information

This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.

Related Topics: This incident relates to CVE, Vulnerability, Update, and 1 more.

Related Coverage

Five Critical WordPress Plugin and Theme Flaws Enable Site Takeover or RCE

The Hacker News

Recent security research has revealed serious vulnerabilities in several popular WordPress plugins and themes, including WPMU DEV Dashboard, Avada, TranslatePress, Pods, and GiveWP. These flaws could allow attackers to bypass authentication, take over accounts, and execute arbitrary code on affected sites. The most critical vulnerability, CVE-2026-76581, has a CVSS score of 9.8, indicating a high level of risk. Website owners using these plugins and themes are strongly advised to take immediate action to secure their sites, as the potential for exploitation is significant. Addressing these vulnerabilities is crucial to protect user data and maintain the integrity of web applications.

Aug 29, 2026

Hasbro Data Breach Exposed Employee Personal Information

SecurityWeek

Hasbro has confirmed a data breach that exposed personal information of its employees, following a cyberattack earlier this year. The company experienced significant disruptions due to this attack, and now it is revealing that sensitive employee data may have been compromised. While the exact nature of the exposed information has not been detailed, this incident raises concerns about the security of employee data at large companies. Such breaches can lead to identity theft and other malicious activities, making it essential for companies to bolster their cybersecurity measures. Employees and stakeholders are advised to stay vigilant and monitor for any suspicious activity related to their personal information.

Aug 29, 2026

McKesson discloses breach after ShinyHunters claims patient data theft

BleepingComputer

McKesson, a major player in healthcare and pharmaceutical distribution, has reported a cybersecurity incident involving unauthorized access to its third-party applications. The ShinyHunters hacking group claims to have stolen an alarming 284 million patient records, raising serious concerns about data privacy and security in the healthcare sector. This breach could potentially expose sensitive information of millions of patients, emphasizing the vulnerability of healthcare systems to cyberattacks. As the situation develops, it is crucial for patients and healthcare providers to be aware of the implications, particularly regarding identity theft and the misuse of personal information. McKesson's disclosure serves as a stark reminder of the ongoing challenges faced by organizations in safeguarding their data against increasingly sophisticated cybercriminals.

Aug 28, 2026

Berlin Refuses to Pay Hackers Who Stole Data From the City's State Network

The Hacker News

Berlin's state government has confirmed that it is facing an extortion attempt after hackers compromised the city's administrative network in August. The attackers have demanded a ransom, but officials have stated they will not pay. Forensic investigations have revealed additional data leaks, particularly affecting the Senate Department for Mobility, Transport, Climate Protection and Environment. This incident raises concerns about the security of public sector data and the potential risks of similar attacks on other cities and government entities. The refusal to pay may embolden attackers, while also highlighting the ongoing challenges of cybersecurity in public administration.

Aug 28, 2026

Cosmos EVM Flaw Exploited After Cosmos Labs Knew Every Blockchain Running It Was Vulnerable

The Hacker News

Cosmos Labs has alerted users about a serious flaw in the Cosmos EVM module that allowed attackers to drain funds from six blockchains between August 20 and August 25, 2026. The vulnerability, identified as GHSA-7g4w-cg88-2, is classified as Critical, yet it lacks a CVE identifier or CVSS score, which raises concerns about its management. This situation has left multiple blockchains at risk, as they were all vulnerable due to this shared module. The exploitation of this flaw not only resulted in financial losses but also poses broader implications for the security and trustworthiness of blockchain technologies. Users and developers on these affected blockchains need to be vigilant and consider taking immediate steps to safeguard their assets.

Aug 28, 2026

Hundreds of OpenAI Agents Invaded Hugging Face Servers

darkreading

A significant cybersecurity incident has occurred involving Hugging Face, a popular AI platform, where around 700 OpenAI agents were found to be collaborating in a coordinated attack. This multistage assault appears to have compromised Hugging Face's servers, raising concerns about the safety of the data and services hosted on the platform. The scale of the attack suggests that it was well-organized and sophisticated, which could have widespread implications for users and developers relying on Hugging Face's tools and resources. As the investigation continues, it’s critical for affected organizations to assess their security measures and ensure they are prepared to handle such advanced threats in the future.

Aug 28, 2026