Critical

AutomationDirect Productivity Suite

All CISA Advisories

Overview

AutomationDirect's Productivity Suite has several critical vulnerabilities that could be exploited by attackers with local or physical access. These vulnerabilities, affecting versions up to 4.6.2.2, include out-of-bounds writes and reads, which could lead to memory corruption, information disclosure, and system instability. Users are strongly advised to update to version 4.7.0.47 or later to mitigate these risks. In the meantime, AutomationDirect recommends several compensating controls, such as disconnecting affected workstations from external networks and restricting access to authorized personnel only. The vulnerabilities affect critical manufacturing sectors worldwide, emphasizing the need for immediate attention from users of the software.

Key Takeaways

  • Affected Systems: AutomationDirect Productivity Suite versions <=v4.6.2.2
  • Action Required: Users should update to AutomationDirect Productivity Suite version 4.
  • Timeline: Newly disclosed

Original Article Summary

View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389, CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerabilities v3 7 AutomationDirect AutomationDirect Productivity Suite Out-of-bounds Write, Out-of-bounds Read, Divide By Zero Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-60063 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-61389 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-60140 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This can lead to exposing sensitive information or causing the affected product to become unstable or unavailable. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-57896 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This could lead to limited information disclosure or disruption of the affected product. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-60073 An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H 4.0 5.2 MEDIUM CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-61378 A divide-by-zero vulnerability in the Productivity Suite allows a local attacker to cause a division by zero leading to a system crash. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-369 Divide By Zero Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 6.8 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Luca Borzacchiello of Nozomi Networks reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use

Impact

AutomationDirect Productivity Suite versions <=v4.6.2.2

Exploitation Status

No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.

Timeline

Newly disclosed

Remediation

Users should update to AutomationDirect Productivity Suite version 4.7.0.47 or above. If an immediate update cannot be applied, recommended compensating controls include disconnecting workstations from external networks, using trusted internal networks, restricting access, configuring whitelisting for applications, employing antivirus or EDR tools, enabling system logs for monitoring, maintaining secure backups, and continuously evaluating risks from outdated firmware.

Additional Information

This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.

Related Topics: This incident relates to Phishing, CVE, Vulnerability, and 3 more.

Related Coverage

Update now: 7-Zip fixes RCE flaw exploitable with malicious archives

BleepingComputer

7-Zip has released version 26.02 to address a serious remote code execution (RCE) vulnerability. This flaw allows attackers to execute malicious code on users' systems if they open specially crafted compressed files. Users of 7-Zip should update to the latest version to protect themselves from potential exploitation. The vulnerability is particularly concerning as it could be exploited easily by tricking users into opening harmful files. Keeping software up to date is crucial in maintaining security and preventing such attacks.

Jul 18, 2026

OpenSSL Fixes HollowByte Memory Exhaustion Bug

Security Affairs

Okta has reported a new vulnerability in OpenSSL, dubbed HollowByte, which allows remote attackers to exploit a flaw that can lead to memory exhaustion on servers. This specific vulnerability is only 11 bytes long, and when exploited, it can cause a server to allocate up to 131 KB of memory. As a result, this could trigger denial-of-service attacks, rendering the affected servers unable to respond to legitimate requests. Organizations using affected versions of OpenSSL should prioritize patching this vulnerability to protect their systems from potential exploitation. The risk is significant, as attackers can exploit this flaw without needing authentication, making it easier for malicious actors to disrupt services.

Jul 18, 2026

WordPress Core "wp2shell" RCE flaws get public exploits, patch now

BleepingComputer

Recent vulnerabilities known as 'wp2shell' have been discovered in WordPress Core, allowing remote code execution. These flaws are particularly concerning because public exploits have now been released, meaning attackers can actively take advantage of them. Administrators of WordPress sites need to act quickly to patch their systems to protect against potential breaches. The urgent nature of this situation is underscored by the fact that these vulnerabilities can compromise the security of websites, putting sensitive data at risk. Users of WordPress should ensure they are running the latest version to mitigate these risks.

Jul 18, 2026

Two new high severity WordPress vulnerabilities, patch immediately!

Help Net Security

WordPress has released a security update, version 7.0.2, to address two significant vulnerabilities that pose risks to users. The first vulnerability, identified as CVE-2026-60137, is a SQL injection issue that could allow attackers to manipulate databases. The second, also CVE-2026-60137, relates to a REST API batch-route confusion that could lead to remote code execution, potentially giving attackers full control over affected systems. The vulnerabilities affect WordPress version 6.9 and earlier. Users are strongly advised to update their installations immediately to mitigate the risks associated with these security flaws.

Jul 18, 2026

2 charged in New York for laundering $43 million from investment scams

SCM feed for Latest

Zhuoying Chen, 27, and Haojie Zhang, 38, have been charged in New York for allegedly laundering $43 million that was obtained through various investment scams. The two men are accused of operating a network that funneled this significant sum of money to China, raising concerns about the scale and sophistication of financial fraud schemes. The case illustrates how cybercriminals are increasingly using complex methods to hide illicit funds, which can undermine legitimate financial systems. Authorities are focusing on these activities to combat financial crimes and protect potential victims from similar scams. The investigation underscores the ongoing challenges law enforcement faces in tracking and prosecuting financial fraud linked to cyber activities.

Jul 17, 2026

New Russian-speaking threat actor UAT-11795 targets US and Europe with novel malware

SCM feed for Latest

A new Russian-speaking hacking group known as UAT-11795 is targeting organizations in the United States and Europe. This group is using innovative malware tools, specifically the Starland Remote Access Trojan (RAT) built with Python and the PowerShell-based WLDR agent, which operates solely in memory. These tools are designed to evade detection through encrypted communications and a unique execution environment. The emergence of UAT-11795 raises concerns for businesses and government entities, as their tactics could lead to significant data breaches or system compromises. As cyber threats continue to evolve, organizations need to be vigilant and enhance their security measures to defend against such sophisticated attacks.

Jul 17, 2026