AutomationDirect Productivity Suite
Overview
AutomationDirect's Productivity Suite has several critical vulnerabilities that could be exploited by attackers with local or physical access. These vulnerabilities, affecting versions up to 4.6.2.2, include out-of-bounds writes and reads, which could lead to memory corruption, information disclosure, and system instability. Users are strongly advised to update to version 4.7.0.47 or later to mitigate these risks. In the meantime, AutomationDirect recommends several compensating controls, such as disconnecting affected workstations from external networks and restricting access to authorized personnel only. The vulnerabilities affect critical manufacturing sectors worldwide, emphasizing the need for immediate attention from users of the software.
Key Takeaways
- Affected Systems: AutomationDirect Productivity Suite versions <=v4.6.2.2
- Action Required: Users should update to AutomationDirect Productivity Suite version 4.
- Timeline: Newly disclosed
Original Article Summary
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker with local or physical access to cause memory corruption, unintended information disclosure, application instability, or a denial-of-service condition in the affected product. The following versions of AutomationDirect Productivity Suite are affected: Productivity Suite <=v4.6.2.2 (CVE-2026-60063, CVE-2026-61389, CVE-2026-60140, CVE-2026-57896, CVE-2026-60073, CVE-2026-61378) CVSS Vendor Equipment Vulnerabilities v3 7 AutomationDirect AutomationDirect Productivity Suite Out-of-bounds Write, Out-of-bounds Read, Divide By Zero Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-60063 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-61389 An out-of-bounds write vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption via a crafted IOCTL request, potentially resulting in privilege escalation or system instability. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.3 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-60140 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This can lead to exposing sensitive information or causing the affected product to become unstable or unavailable. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-57896 An out-of-bounds read vulnerability in the Productivity Suite allows a local attacker to trigger kernel memory corruption by sending a crafted IOCTL request. This could lead to limited information disclosure or disruption of the affected product. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.1 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:H 4.0 6.9 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-60073 An out-of-bounds read in the Productivity Suite allows a physical attacker to control the length of data sent to a USB device. This can lead to a system crash or disclosure of kernel memory. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-125 Out-of-bounds Read Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:P/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:H 4.0 5.2 MEDIUM CVSS:4.0/AV:P/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-61378 A divide-by-zero vulnerability in the Productivity Suite allows a local attacker to cause a division by zero leading to a system crash. View CVE Details Affected Products AutomationDirect Productivity Suite Vendor: AutomationDirect Product Version: AutomationDirect Productivity Suite: <=v4.6.2.2 Product Status: known_affected Remediations Mitigation AutomationDirect recommends that users update Productivity suite to v4.7.0.47 and above https://www.automationdirect.com/support/software-downloads. https://www.automationdirect.com/support/software-downloads Mitigation If the update cannot be applied right away, the following compensating controls are recommended until the upgrade can be performed. Mitigation Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure. Mitigation Use only trusted, dedicated internal networks or air-gapped systems for device communication. Mitigation Restrict both physical and logical access to authorized personnel only. Mitigation Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software. Mitigation Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts. Mitigation Enable and regularly review system logs to detect suspicious or unauthorized activity. Mitigation Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident. Mitigation Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly. Relevant CWE: CWE-369 Divide By Zero Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.5 MEDIUM CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H 4.0 6.8 MEDIUM CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N Acknowledgments Luca Borzacchiello of Nozomi Networks reported these vulnerabilities to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting these vulnerabilities has been reported to CISA at this time. These vulnerabilities are not exploitable remotely. Revision History Initial Release Date: 2026-07-16 Date Revision Summary 2026-07-16 1 Initial Publication Legal Notice and Terms of Use
Impact
AutomationDirect Productivity Suite versions <=v4.6.2.2
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Newly disclosed
Remediation
Users should update to AutomationDirect Productivity Suite version 4.7.0.47 or above. If an immediate update cannot be applied, recommended compensating controls include disconnecting workstations from external networks, using trusted internal networks, restricting access, configuring whitelisting for applications, employing antivirus or EDR tools, enabling system logs for monitoring, maintaining secure backups, and continuously evaluating risks from outdated firmware.
Additional Information
This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.
Related Topics: This incident relates to Phishing, CVE, Vulnerability, and 3 more.