Siemens Siveillance Video
Overview
Siemens has identified a serious vulnerability in its Siveillance Video Management Servers that could allow attackers to execute arbitrary code remotely. This flaw, classified as CVE-2026-3014, affects several versions of the software, specifically Siveillance Video V2023 R3 versions prior to 23.3.27, V2024 R1 versions before 24.1.16, and V2025 versions below 25.1.15. Siemens urges users to update their systems to the latest versions to mitigate the risk. The vulnerability poses a significant threat to critical infrastructure sectors, including manufacturing and communications, making it crucial for organizations using these systems to act promptly. Users are also advised to enhance their network security measures to protect against potential exploitation.
Key Takeaways
- Affected Systems: Siemens Siveillance Video V2023 R3 < V23.3.27, Siemens Siveillance Video V2024 R1 < V24.1.16, Siemens Siveillance Video V2025 < V25.1.15
- Action Required: Update to Siveillance Video V2023 R3 HotfixRev27 or later, V2024 R1 HotfixRev16 or later, and V2025 HotfixRev15 or later.
- Timeline: Newly disclosed
Original Article Summary
View CSAF Summary Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Siveillance Video are affected: Siveillance Video V2023 R3 vers:intdot/<23.3.27 (CVE-2026-3014) Siveillance Video V2024 R1 vers:intdot/<24.1.16 (CVE-2026-3014) Siveillance Video V2025 vers:intdot/<25.1.15 (CVE-2026-3014) CVSS Vendor Equipment Vulnerabilities v3 9.1 Siemens Siemens Siveillance Video Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Background Critical Infrastructure Sectors: Critical Manufacturing, Communications, Commercial Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-3014 Milestone has released a new version of XProtect® (and several cumulative patch updates) which fix security vulnerability in Management Server API. The vulnerability causes users with edit permissions to the Management Server to be able to execute arbitrary code in context of the Management Server Service. View CVE Details Affected Products Siemens Siveillance Video Vendor: Siemens Product Version: Siveillance Video V2023 R3 < V23.3.27, Siveillance Video V2024 R1 < V24.1.16, Siveillance Video V2025 < V25.1.15 Product Status: known_affected Remediations Vendor fix Update to V23.3 HotfixRev27 or later version https://support.industry.siemens.com/cs/ww/en/view/109827783/ Vendor fix Update to V24.1 HotfixRev16 or later version https://support.industry.siemens.com/cs/ww/en/view/109976123/ Vendor fix Update to V25.1 HotfixRev15 or later version https://support.industry.siemens.com/cs/ww/en/view/109988670/ Relevant CWE: CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H Acknowledgments Milestone PSIRT reported this vulnerability to Siemens General Recommendations As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment. Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens SSA-825228 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-13 2 Initial CISA Republication of Siemens SSA-825228 advisory Legal Notice and Terms of Use
Impact
Siemens Siveillance Video V2023 R3 < V23.3.27, Siemens Siveillance Video V2024 R1 < V24.1.16, Siemens Siveillance Video V2025 < V25.1.15
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Newly disclosed
Remediation
Update to Siveillance Video V2023 R3 HotfixRev27 or later, V2024 R1 HotfixRev16 or later, and V2025 HotfixRev15 or later.
Additional Information
This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.
Related Topics: This incident relates to CVE, Vulnerability, Patch, and 2 more.