Siemens has identified a serious vulnerability in its SIMATIC IoT2050 Advanced devices that run Industrial OS with Node-RED installed. The flaw arises from a lack of authentication on the Node-RED HTTP interface, which could allow remote attackers to access and manipulate system commands on the server without any authentication. This means they could create harmful flows and execute arbitrary code with full system privileges. Siemens has urged users to update their devices to version 4.3.4.1 or later to mitigate this risk. The affected devices are used across various critical infrastructure sectors, including chemical, manufacturing, energy, and transportation, highlighting the need for immediate action to protect against potential exploitation.
Key Takeaways
- Affected Systems: Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) running Industrial OS with Node-RED installed, versions < 4.3.4.1.
- Action Required: Update to version 4.
- Timeline: Disclosed on August 11, 2026
Original Article Summary
View CSAF Summary SIMATIC IoT2050 Advanced devices running Industrial OS with Node-RED installed contain a missing authentication vulnerability in the Node-RED HTTP interface that could allow an unauthenticated remote attacker to create malicious flows and execute arbitrary code on the underlying server with maximum privileges. Siemens has released a new version for SIMATIC IoT2050 Advanced and strongly recommends to update to the latest version. The following versions of Siemens SIMATIC IoT2050 Advanced are affected: SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) vers:intdot/<4.3.4.1 CVSS Vendor Equipment Vulnerabilities v3 10 Siemens Siemens SIMATIC IoT2050 Advanced Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Chemical, Critical Manufacturing, Energy, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-58115 Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges. View CVE Details Affected Products Siemens SIMATIC IoT2050 Advanced Vendor: Siemens Product Version: SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) < V4.3.4.1 running Industrial OS with Node-RED installed Product Status: known_affected Remediations Mitigation Harden the Node-RED installation (see Node-RED User Guide) Mitigation Uninstall Node-RED Vendor fix Update to V4.3.4.1 or later version https://support.industry.siemens.com/cs/ww/en/view/109741799/ Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 10 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-834709 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-08-11 Date Revision Summary 2026-08-11 1 Publication Date 2026-08-25 2 Initial CISA Republication of Siemens ProductCERT SSA-834709 advisory Legal Notice and Terms of Use
Impact
Siemens SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) running Industrial OS with Node-RED installed, versions < 4.3.4.1.
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Disclosed on August 11, 2026
Remediation
Update to version 4.3.4.1 or later. Harden the Node-RED installation as per the Node-RED User Guide. Alternatively, uninstall Node-RED.