Mitsubishi Electric CNC Series (Update A)
Overview
Mitsubishi Electric has identified a vulnerability affecting several models in its CNC Series, specifically relating to improper validation of input indices. This flaw, designated as CVE-2025-2399, can be exploited remotely, leading to an out-of-bounds read that could disrupt service. Affected models include the M800VW, M800VS, M80V, and several others across different series. Users of these products are urged to update to specific fixed versions to prevent potential exploitation. Additionally, Mitsubishi Electric recommends using firewalls, VPNs, and IP filters as interim measures to secure their systems while waiting for updates.
Key Takeaways
- Affected Systems: Mitsubishi Electric M800VW (BND-2051W000) <=BB, Mitsubishi Electric M800VS (BND-2052W000) <=BB, Mitsubishi Electric M80V (BND-2053W000) <=BB, Mitsubishi Electric M80VW (BND-2054W000) <=BB, Mitsubishi Electric M800W (BND-2005W000) <=FM, Mitsubishi Electric M800S (BND-2006W000) <=FM, Mitsubishi Electric M80 (BND-2007W000) <=FM, Mitsubishi Electric M80W (BND-2008W000) <=FM, Mitsubishi Electric E80 (BND-2009W000) <=FM, Mitsubishi Electric C80 (BND-2036W000) vers:all/*, Mitsubishi Electric M750VW (BND-1015W002) <=LJ, Mitsubishi Electric M730VW (BND-1015W000) <=LJ, Mitsubishi Electric M720VW (BND-1015W000) <=LJ, Mitsubishi Electric M750VS (BND-1012W002) <=LJ, Mitsubishi Electric M730VS (BND-1012W000) <=LJ, Mitsubishi Electric M720VS (BND-1012W000) <=LJ, Mitsubishi Electric M70V (BND-1018W000) <=LJ, Mitsubishi Electric E70 (BND-1022W000) <=LJ.
- Action Required: Users should apply the fixed versions: BC or later for M800VW, M800VS, M80V, and M80VW; FN or later for M800W, M800S, M80, M80W, and E80; LK or later for M750VW, M730VW, M720VW, M750VS, M730VS, M720VS, M70V, and E70.
- Timeline: Newly disclosed
Original Article Summary
View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products. The following versions of Mitsubishi Electric CNC Series (Update A) are affected: Mitsubishi Electric M800VW (BND-2051W000) <=BB (CVE-2025-2399) Mitsubishi Electric M800VS (BND-2052W000) <=BB (CVE-2025-2399) Mitsubishi Electric M80V (BND-2053W000) <=BB (CVE-2025-2399) Mitsubishi Electric M80VW (BND-2054W000) <=BB (CVE-2025-2399) Mitsubishi Electric M800W (BND-2005W000) <=FM (CVE-2025-2399) Mitsubishi Electric M800S (BND-2006W000) <=FM (CVE-2025-2399) Mitsubishi Electric M80 (BND-2007W000) <=FM (CVE-2025-2399) Mitsubishi Electric M80W (BND-2008W000) <=FM (CVE-2025-2399) Mitsubishi Electric E80 (BND-2009W000) <=FM (CVE-2025-2399) Mitsubishi Electric C80 (BND-2036W000) vers:all/* (CVE-2025-2399) Mitsubishi Electric M750VW (BND-1015W002) <=LJ (CVE-2025-2399) Mitsubishi Electric M730VW (BND-1015W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M720VW (BND-1015W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M750VS (BND-1012W002) <=LJ (CVE-2025-2399) Mitsubishi Electric M730VS (BND-1012W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M720VS (BND-1012W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M70V (BND-1018W000) <=LJ (CVE-2025-2399) Mitsubishi Electric E70 (BND-1022W000) <=LJ (CVE-2025-2399) CVSS Vendor Equipment Vulnerabilities v3 5.9 Mitsubishi Electric Mitsubishi Electric CNC Series (Update A) Improper Validation of Specified Index, Position, or Offset in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-2399 Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683. View CVE Details Affected Products Mitsubishi Electric CNC Series (Update A) Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric M800VW (BND-2051W000): <=BB, Mitsubishi Electric M800VS (BND-2052W000): <=BB, Mitsubishi Electric M80V (BND-2053W000): <=BB, Mitsubishi Electric M80VW (BND-2054W000): <=BB, Mitsubishi Electric M800W (BND-2005W000): <=FM, Mitsubishi Electric M800S (BND-2006W000): <=FM, Mitsubishi Electric M80 (BND-2007W000): <=FM, Mitsubishi Electric M80W (BND-2008W000): <=FM, Mitsubishi Electric E80 (BND-2009W000): <=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): <=LJ, Mitsubishi Electric M730VW (BND-1015W000): <=LJ, Mitsubishi Electric M720VW (BND-1015W000): <=LJ, Mitsubishi Electric M750VS (BND-1012W002): <=LJ, Mitsubishi Electric M730VS (BND-1012W000): <=LJ, Mitsubishi Electric M720VS (BND-1012W000): <=LJ, Mitsubishi Electric M70V (BND-1018W000): <=LJ, Mitsubishi Electric E70 (BND-1022W000): <=LJ Product Status: known_affected Remediations Vendor fix Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW (BND-2051W000), M800VS (BND-2052W000), M80V (BND-2053W000), and M80VW (BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Vendor fix Please apply the fixed version (FN or later) for Mitsubishi Electric M800W (BND-2005W000), M800S (BND-2006W000), M80 (BND-2007W000), M80W (BND-2008W000), and E80 (BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Vendor fix Please apply the fixed version (LK or later) for Mitsubishi Electric M750VW (BND-1015W002), M730VW (BND-1015W000), M720VW (BND-1015W000), M750VS (BND-1012W002), M730VS (BND-1012W000), M720VS (BND-1012W000), M70V (BND-1018W000), and E70 (BND-1022W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html ": M800V/M80V Series Instruction Manual "16. Appendix 3 IP Address Filter Setting Function", M800/M80/E80 Series Instruction Manual "15. Appendix 2 IP Address Filter Setting Function". https://www.mitsubishielectric.com/fa/download/index.html Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Mitsubishi Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2025-022 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication 2026-03-19 2 CISA Republication - Initial CISA Republication of Mitsubishi Electric V20250121-001#02 advisory 2026-08-27 3 Removed Software Tools NC Trainer2 and Software Tools NC Trainer2 plus, from affected products. And added M700V/M70V/E70 Series as fixed products. 2026-08-27 4 CISA Republication update based on Mitsubishi Electric 2025-022 advisory Legal Notice and Terms of Use
Impact
Mitsubishi Electric M800VW (BND-2051W000) <=BB, Mitsubishi Electric M800VS (BND-2052W000) <=BB, Mitsubishi Electric M80V (BND-2053W000) <=BB, Mitsubishi Electric M80VW (BND-2054W000) <=BB, Mitsubishi Electric M800W (BND-2005W000) <=FM, Mitsubishi Electric M800S (BND-2006W000) <=FM, Mitsubishi Electric M80 (BND-2007W000) <=FM, Mitsubishi Electric M80W (BND-2008W000) <=FM, Mitsubishi Electric E80 (BND-2009W000) <=FM, Mitsubishi Electric C80 (BND-2036W000) vers:all/*, Mitsubishi Electric M750VW (BND-1015W002) <=LJ, Mitsubishi Electric M730VW (BND-1015W000) <=LJ, Mitsubishi Electric M720VW (BND-1015W000) <=LJ, Mitsubishi Electric M750VS (BND-1012W002) <=LJ, Mitsubishi Electric M730VS (BND-1012W000) <=LJ, Mitsubishi Electric M720VS (BND-1012W000) <=LJ, Mitsubishi Electric M70V (BND-1018W000) <=LJ, Mitsubishi Electric E70 (BND-1022W000) <=LJ.
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Newly disclosed
Remediation
Users should apply the fixed versions: BC or later for M800VW, M800VS, M80V, and M80VW; FN or later for M800W, M800S, M80, M80W, and E80; LK or later for M750VW, M730VW, M720VW, M750VS, M730VS, M720VS, M70V, and E70. For those unable to update immediately, Mitsubishi Electric recommends using firewalls, VPNs, IP filters, restricting physical access, and installing antivirus software on PCs accessing affected products.
Additional Information
This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.