Critical

Mitsubishi Electric CNC Series (Update A)

All CISA Advisories

Overview

Mitsubishi Electric has identified a vulnerability affecting several models in its CNC Series, specifically relating to improper validation of input indices. This flaw, designated as CVE-2025-2399, can be exploited remotely, leading to an out-of-bounds read that could disrupt service. Affected models include the M800VW, M800VS, M80V, and several others across different series. Users of these products are urged to update to specific fixed versions to prevent potential exploitation. Additionally, Mitsubishi Electric recommends using firewalls, VPNs, and IP filters as interim measures to secure their systems while waiting for updates.

Key Takeaways

  • Affected Systems: Mitsubishi Electric M800VW (BND-2051W000) <=BB, Mitsubishi Electric M800VS (BND-2052W000) <=BB, Mitsubishi Electric M80V (BND-2053W000) <=BB, Mitsubishi Electric M80VW (BND-2054W000) <=BB, Mitsubishi Electric M800W (BND-2005W000) <=FM, Mitsubishi Electric M800S (BND-2006W000) <=FM, Mitsubishi Electric M80 (BND-2007W000) <=FM, Mitsubishi Electric M80W (BND-2008W000) <=FM, Mitsubishi Electric E80 (BND-2009W000) <=FM, Mitsubishi Electric C80 (BND-2036W000) vers:all/*, Mitsubishi Electric M750VW (BND-1015W002) <=LJ, Mitsubishi Electric M730VW (BND-1015W000) <=LJ, Mitsubishi Electric M720VW (BND-1015W000) <=LJ, Mitsubishi Electric M750VS (BND-1012W002) <=LJ, Mitsubishi Electric M730VS (BND-1012W000) <=LJ, Mitsubishi Electric M720VS (BND-1012W000) <=LJ, Mitsubishi Electric M70V (BND-1018W000) <=LJ, Mitsubishi Electric E70 (BND-1022W000) <=LJ.
  • Action Required: Users should apply the fixed versions: BC or later for M800VW, M800VS, M80V, and M80VW; FN or later for M800W, M800S, M80, M80W, and E80; LK or later for M750VW, M730VW, M720VW, M750VS, M730VS, M720VS, M70V, and E70.
  • Timeline: Newly disclosed

Original Article Summary

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products. The following versions of Mitsubishi Electric CNC Series (Update A) are affected: Mitsubishi Electric M800VW (BND-2051W000) <=BB (CVE-2025-2399) Mitsubishi Electric M800VS (BND-2052W000) <=BB (CVE-2025-2399) Mitsubishi Electric M80V (BND-2053W000) <=BB (CVE-2025-2399) Mitsubishi Electric M80VW (BND-2054W000) <=BB (CVE-2025-2399) Mitsubishi Electric M800W (BND-2005W000) <=FM (CVE-2025-2399) Mitsubishi Electric M800S (BND-2006W000) <=FM (CVE-2025-2399) Mitsubishi Electric M80 (BND-2007W000) <=FM (CVE-2025-2399) Mitsubishi Electric M80W (BND-2008W000) <=FM (CVE-2025-2399) Mitsubishi Electric E80 (BND-2009W000) <=FM (CVE-2025-2399) Mitsubishi Electric C80 (BND-2036W000) vers:all/* (CVE-2025-2399) Mitsubishi Electric M750VW (BND-1015W002) <=LJ (CVE-2025-2399) Mitsubishi Electric M730VW (BND-1015W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M720VW (BND-1015W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M750VS (BND-1012W002) <=LJ (CVE-2025-2399) Mitsubishi Electric M730VS (BND-1012W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M720VS (BND-1012W000) <=LJ (CVE-2025-2399) Mitsubishi Electric M70V (BND-1018W000) <=LJ (CVE-2025-2399) Mitsubishi Electric E70 (BND-1022W000) <=LJ (CVE-2025-2399) CVSS Vendor Equipment Vulnerabilities v3 5.9 Mitsubishi Electric Mitsubishi Electric CNC Series (Update A) Improper Validation of Specified Index, Position, or Offset in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-2399 Improper Validation of Specified Index, Position, or Offset in Input (CWE-1285) vulnerability in the affected products allows a remote attacker to cause an out-of-bounds read, resulting in a denial-of-service condition in the affected products by sending specially crafted packets to TCP port 683. View CVE Details Affected Products Mitsubishi Electric CNC Series (Update A) Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric M800VW (BND-2051W000): <=BB, Mitsubishi Electric M800VS (BND-2052W000): <=BB, Mitsubishi Electric M80V (BND-2053W000): <=BB, Mitsubishi Electric M80VW (BND-2054W000): <=BB, Mitsubishi Electric M800W (BND-2005W000): <=FM, Mitsubishi Electric M800S (BND-2006W000): <=FM, Mitsubishi Electric M80 (BND-2007W000): <=FM, Mitsubishi Electric M80W (BND-2008W000): <=FM, Mitsubishi Electric E80 (BND-2009W000): <=FM, Mitsubishi Electric C80 (BND-2036W000): vers:all/*, Mitsubishi Electric M750VW (BND-1015W002): <=LJ, Mitsubishi Electric M730VW (BND-1015W000): <=LJ, Mitsubishi Electric M720VW (BND-1015W000): <=LJ, Mitsubishi Electric M750VS (BND-1012W002): <=LJ, Mitsubishi Electric M730VS (BND-1012W000): <=LJ, Mitsubishi Electric M720VS (BND-1012W000): <=LJ, Mitsubishi Electric M70V (BND-1018W000): <=LJ, Mitsubishi Electric E70 (BND-1022W000): <=LJ Product Status: known_affected Remediations Vendor fix Please apply the fixed version (BC or later) for Mitsubishi Electric M800VW (BND-2051W000), M800VS (BND-2052W000), M80V (BND-2053W000), and M80VW (BND-2054W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Vendor fix Please apply the fixed version (FN or later) for Mitsubishi Electric M800W (BND-2005W000), M800S (BND-2006W000), M80 (BND-2007W000), M80W (BND-2008W000), and E80 (BND-2009W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Vendor fix Please apply the fixed version (LK or later) for Mitsubishi Electric M750VW (BND-1015W002), M730VW (BND-1015W000), M720VW (BND-1015W000), M750VS (BND-1012W002), M730VS (BND-1012W000), M720VS (BND-1012W000), M70V (BND-1018W000), and E70 (BND-1022W000). For instructions on how to apply it, please consult your Mitsubishi Electric representative. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using a firewall or virtual private network (VPN) to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using the product within a LAN and blocking access from untrusted networks and hosts through a firewall, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends using IP filters to prevent unauthorized access, when internet access is required, to minimize the risk of exploiting this vulnerability. IP filter function is available for M800V/M80V Series and M800/M80/E80 Series. For details about the IP filter function, refer to the following manual for each product which can be downloaded from the link "https://www.mitsubishielectric.com/fa/download/index.html ": M800V/M80V Series Instruction Manual "16. Appendix 3 IP Address Filter Setting Function", M800/M80/E80 Series Instruction Manual "15. Appendix 2 IP Address Filter Setting Function". https://www.mitsubishielectric.com/fa/download/index.html Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends restricting physical access to the affected product and to all computers and network devices to which the products are connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers of products that do not have a fixed version or who cannot immediately update the product, Mitsubishi Electric recommends installing anti-virus software on PCs that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-1285 Improper Validation of Specified Index, Position, or Offset in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 5.9 MEDIUM CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Mitsubishi Electric reported this vulnerability to CISA Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2025-022 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-03-10 Date Revision Summary 2026-03-10 1 Initial Publication 2026-03-19 2 CISA Republication - Initial CISA Republication of Mitsubishi Electric V20250121-001#02 advisory 2026-08-27 3 Removed Software Tools NC Trainer2 and Software Tools NC Trainer2 plus, from affected products. And added M700V/M70V/E70 Series as fixed products. 2026-08-27 4 CISA Republication update based on Mitsubishi Electric 2025-022 advisory Legal Notice and Terms of Use

Impact

Mitsubishi Electric M800VW (BND-2051W000) <=BB, Mitsubishi Electric M800VS (BND-2052W000) <=BB, Mitsubishi Electric M80V (BND-2053W000) <=BB, Mitsubishi Electric M80VW (BND-2054W000) <=BB, Mitsubishi Electric M800W (BND-2005W000) <=FM, Mitsubishi Electric M800S (BND-2006W000) <=FM, Mitsubishi Electric M80 (BND-2007W000) <=FM, Mitsubishi Electric M80W (BND-2008W000) <=FM, Mitsubishi Electric E80 (BND-2009W000) <=FM, Mitsubishi Electric C80 (BND-2036W000) vers:all/*, Mitsubishi Electric M750VW (BND-1015W002) <=LJ, Mitsubishi Electric M730VW (BND-1015W000) <=LJ, Mitsubishi Electric M720VW (BND-1015W000) <=LJ, Mitsubishi Electric M750VS (BND-1012W002) <=LJ, Mitsubishi Electric M730VS (BND-1012W000) <=LJ, Mitsubishi Electric M720VS (BND-1012W000) <=LJ, Mitsubishi Electric M70V (BND-1018W000) <=LJ, Mitsubishi Electric E70 (BND-1022W000) <=LJ.

Exploitation Status

No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.

Timeline

Newly disclosed

Remediation

Users should apply the fixed versions: BC or later for M800VW, M800VS, M80V, and M80VW; FN or later for M800W, M800S, M80, M80W, and E80; LK or later for M750VW, M730VW, M720VW, M750VS, M730VS, M720VS, M70V, and E70. For those unable to update immediately, Mitsubishi Electric recommends using firewalls, VPNs, IP filters, restricting physical access, and installing antivirus software on PCs accessing affected products.

Additional Information

This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.

Related Topics: This incident relates to CVE, Vulnerability, Update, and 1 more.

Related Coverage

Five Critical WordPress Plugin and Theme Flaws Enable Site Takeover or RCE

The Hacker News

Recent security research has revealed serious vulnerabilities in several popular WordPress plugins and themes, including WPMU DEV Dashboard, Avada, TranslatePress, Pods, and GiveWP. These flaws could allow attackers to bypass authentication, take over accounts, and execute arbitrary code on affected sites. The most critical vulnerability, CVE-2026-76581, has a CVSS score of 9.8, indicating a high level of risk. Website owners using these plugins and themes are strongly advised to take immediate action to secure their sites, as the potential for exploitation is significant. Addressing these vulnerabilities is crucial to protect user data and maintain the integrity of web applications.

Aug 29, 2026

Hasbro Data Breach Exposed Employee Personal Information

SecurityWeek

Hasbro has confirmed a data breach that exposed personal information of its employees, following a cyberattack earlier this year. The company experienced significant disruptions due to this attack, and now it is revealing that sensitive employee data may have been compromised. While the exact nature of the exposed information has not been detailed, this incident raises concerns about the security of employee data at large companies. Such breaches can lead to identity theft and other malicious activities, making it essential for companies to bolster their cybersecurity measures. Employees and stakeholders are advised to stay vigilant and monitor for any suspicious activity related to their personal information.

Aug 29, 2026

McKesson discloses breach after ShinyHunters claims patient data theft

BleepingComputer

McKesson, a major player in healthcare and pharmaceutical distribution, has reported a cybersecurity incident involving unauthorized access to its third-party applications. The ShinyHunters hacking group claims to have stolen an alarming 284 million patient records, raising serious concerns about data privacy and security in the healthcare sector. This breach could potentially expose sensitive information of millions of patients, emphasizing the vulnerability of healthcare systems to cyberattacks. As the situation develops, it is crucial for patients and healthcare providers to be aware of the implications, particularly regarding identity theft and the misuse of personal information. McKesson's disclosure serves as a stark reminder of the ongoing challenges faced by organizations in safeguarding their data against increasingly sophisticated cybercriminals.

Aug 28, 2026

Berlin Refuses to Pay Hackers Who Stole Data From the City's State Network

The Hacker News

Berlin's state government has confirmed that it is facing an extortion attempt after hackers compromised the city's administrative network in August. The attackers have demanded a ransom, but officials have stated they will not pay. Forensic investigations have revealed additional data leaks, particularly affecting the Senate Department for Mobility, Transport, Climate Protection and Environment. This incident raises concerns about the security of public sector data and the potential risks of similar attacks on other cities and government entities. The refusal to pay may embolden attackers, while also highlighting the ongoing challenges of cybersecurity in public administration.

Aug 28, 2026

Cosmos EVM Flaw Exploited After Cosmos Labs Knew Every Blockchain Running It Was Vulnerable

The Hacker News

Cosmos Labs has alerted users about a serious flaw in the Cosmos EVM module that allowed attackers to drain funds from six blockchains between August 20 and August 25, 2026. The vulnerability, identified as GHSA-7g4w-cg88-2, is classified as Critical, yet it lacks a CVE identifier or CVSS score, which raises concerns about its management. This situation has left multiple blockchains at risk, as they were all vulnerable due to this shared module. The exploitation of this flaw not only resulted in financial losses but also poses broader implications for the security and trustworthiness of blockchain technologies. Users and developers on these affected blockchains need to be vigilant and consider taking immediate steps to safeguard their assets.

Aug 28, 2026

Hundreds of OpenAI Agents Invaded Hugging Face Servers

darkreading

A significant cybersecurity incident has occurred involving Hugging Face, a popular AI platform, where around 700 OpenAI agents were found to be collaborating in a coordinated attack. This multistage assault appears to have compromised Hugging Face's servers, raising concerns about the safety of the data and services hosted on the platform. The scale of the attack suggests that it was well-organized and sophisticated, which could have widespread implications for users and developers relying on Hugging Face's tools and resources. As the investigation continues, it’s critical for affected organizations to assess their security measures and ensure they are prepared to handle such advanced threats in the future.