Critical

Mitsubishi Electric Multiple FA Products (Update D)

All CISA Advisories

Overview

Mitsubishi Electric has disclosed a significant vulnerability affecting multiple models of its CC-Link IE TSN Remote I/O products. This flaw, identified as CVE-2025-3511, allows remote attackers to trigger a denial-of-service (DoS) condition by sending specially crafted UDP packets. Affected devices include various models of CC-Link IE TSN Remote I/O modules, Analog-Digital and Digital-Analog Converter modules, FPGA modules, and MELSEC iQ series components. The potential for disruption is considerable, as it could lead to communication delays or complete service outages in critical manufacturing environments. Companies using these affected products should prioritize immediate action to mitigate risks associated with this vulnerability.

Key Takeaways

  • Affected Systems: Mitsubishi Electric CC-Link IE TSN Remote I/O modules (NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, NZ2GN2B1-16TE), CC-Link IE TSN Analog-Digital Converter modules, Digital-Analog Converter modules, FPGA modules, MELSEC iQ-R Series CPU modules (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, R120ENCPU), and MELSEC iQ-F Series modules.
  • Action Required: Users should apply patches or updates provided by Mitsubishi Electric for the affected products.
  • Timeline: Newly disclosed

Original Article Summary

View CSAF Summary Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition, a timeout error, or a communication delay by sending a specially crafted UDP packet to the product. The following versions of Mitsubishi Electric Multiple FA Products (Update D) are affected: Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16D <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16T <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE <=09 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4 <=07 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4 <=07 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4 <=07 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4 <=07 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41P01 01 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41D01 01 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41PD02 01 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300 <=1.08J (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60 <=1.08J (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2 <=26 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP <=10 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX <=05 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series Ethernet Interface Module RJ71EN71 <=85 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2GACP610-60 <=05 (CVE-2025-3511) Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2KT-NPETNG51 <=05 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS <=1.020 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET <=1.200 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP <=1.106 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CPU module R04ENCPU (Network Part) <=85 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CPU module R08ENCPU (Network Part) <=85 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CPU module R16ENCPU (Network Part) <=85 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CPU module R32ENCPU (Network Part) <=85 (CVE-2025-3511) Mitsubishi Electric MELSEC iQ-R Series CPU module R120ENCPU (Network Part) <=85 (CVE-2025-3511) CVSS Vendor Equipment Vulnerabilities v3 7.5 Mitsubishi Electric Mitsubishi Electric Multiple FA Products (Update D) Improper Validation of Specified Quantity in Input Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2025-3511 A denial-of-service (DoS) vulnerability due to Improper Validation of Specified Quantity in Input (CWE-1284) exists in the Ethernet function of multiple FA products. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition by sending a specially crafted UDP packet if CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, NZ2GN2B1-16TE, CC-Link IE TSN Analog-Digital Converter modules NZ2GN2S-60AD4, NZ2GN2B-60AD4, CC-Link IE TSN Digital-Analog Converter modules NZ2GN2S-60DA4 and NZ2GN2B-60DA4, CC-Link IE TSN FPGA modules NZ2GN2S-D41P01, NZ2GN2S-D41D01, NZ2GN2S-D41PD02, CC-Link IE TSN Remote Station Communication LSIs CP620 with GbE-PHY NZ2GACP620-300, and NZ2GACP620-60 does not receive a valid UDP packet within 3 seconds. This vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition on MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, MELSEC iQ-R Series Ethernet Interface Module RJ71EN71, CC-Link IE TSN master/local Station Communication LSIs CP610 NZ2GACP610-60, NZ2KT-NPETNG51, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS, MELSEC iQ-R Series CPU module R04ENCPU (Network part), R08ENCPU (Network part), R16ENCPU (Network part), R32ENCPU (Network part), and R120ENCPU (Network part), by sending a specially crafted UDP packet. Or this vulnerability could allow a remote attacker to cause a communication delay in Simple CPU communication on MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET and FX5-ENET/IP Ethernet Module FX5-ENET/IP, by sending a specially crafted UDP packet. A system reset of the product is required for recovery in all cases above. Additionally, this vulnerability could allow a remote attacker to cause a timeout error in CC-Link IEF Basic communication on MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET and FX5-ENET/IP Ethernet Module FX5-ENET/IP, by sending a specially crafted UDP packet. Even if a timeout error occurs, communication will be restored once the affected product starts receiving valid UDP packets. View CVE Details Affected Products Mitsubishi Electric Multiple FA Products (Update D) Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DTE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32TE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DT: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-32DTE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCF1-32T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GNCE3-32DT: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A4-16DE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A2-16TE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DT: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN12A42-16DTE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-16TE: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16D: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16T: <=09, Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2B1-16TE: <=09, Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2S-60AD4: <=07, Mitsubishi Electric CC-Link IE TSN Analog-Digital Converter module NZ2GN2B-60AD4: <=07, Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2S-60DA4: <=07, Mitsubishi Electric CC-Link IE TSN Digital-Analog Converter module NZ2GN2B-60DA4: <=07, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41P01: 01, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41D01: 01, Mitsubishi Electric CC-Link IE TSN FPGA module NZ2GN2S-D41PD02: 01, Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-300: <=1.08J, Mitsubishi Electric CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY NZ2GACP620-60: <=1.08J, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2: <=26, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP: <=10, Mitsubishi Electric MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX: <=05, Mitsubishi Electric MELSEC iQ-R Series Ethernet Interface Module RJ71EN71: <=85, Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2GACP610-60: <=05, Mitsubishi Electric CC-Link IE TSN master/local Station Communication LSI CP610 NZ2KT-NPETNG51: <=05, Mitsubishi Electric MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS: <=1.020, Mitsubishi Electric MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET: <=1.200, Mitsubishi Electric MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP: <=1.106, Mitsubishi Electric MELSEC iQ-R Series CPU module R04ENCPU (Network Part): <=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R08ENCPU (Network Part): <=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R16ENCPU (Network Part): <=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R32ENCPU (Network Part): <=85, Mitsubishi Electric MELSEC iQ-R Series CPU module R120ENCPU (Network Part): <=85 Product Status: known_affected Remediations Vendor fix Mitsubishi Electric is releasing fixed version 10 or later for CC-Link IE TSN Remote I/O modules NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, and NZ2GN2B1-16TE. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf." https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 08 or later for CC-Link IE TSN Analog-Digital Converter modules NZ2GN2S-60AD4 and NZ2GN2B-60AD4. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 08 or later for CC-Link IE TSN Digital-Analog Converter modules NZ2GN2S-60DA4 and NZ2GN2B-60DA4. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 02 or later for CC-Link IE TSN FPGA modules NZ2GN2S-D41P01, NZ2GN2S-D41D01, and NZ2GN2S-D41PD02. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.09K or later for CC-Link IE TSN Remote Station Communication LSIs CP620 with GbE-PHY NZ2GACP620-300 or NZ2GACP620-60. Please download the CP620 sample code from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 28 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-T2. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 13 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-EIP. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 07 or later for MELSEC iQ-R Series CC-Link IE TSN Master/Local Module RJ71GN11-SX. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 86 or later for MELSEC iQ-R Series Ethernet Interface Module RJ71EN71. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 06 or later for CC-Link IE TSN master/local Station Communication LSIs CP610 NZ2GACP610-60 and NZ2KT-NPETNG51. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.030 or later for MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module FX5-CCLGN-MS. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.210 or later for MELSEC iQ-F Series FX5 Ethernet Module FX5-ENET. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed version 1.107 or later for MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP. Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Vendor fix Mitsubishi Electric is releasing fixed network part firmware version 86 or later for MELSEC iQ-R Series CPU module R04ENCPU (Network part), R08ENCPU (Network part), R16ENCPU (Network part), R32ENCPU (Network part), and R120ENCPU (Network part). Please download the fixed update file from the link "https://www.mitsubishielectric.com/fa/download/index.html" and install it. For more information on the fixed version, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-001_en.pdf". https://www.mitsubishielectric.com/fa/download/index.html Mitigation For customers of the affected products, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc. to prevent unauthorized access when internet access is required, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends using within a LAN and blocking access from untrusted networks and hosts through firewalls, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends restricting physical access to the products and the LAN to which they are connected, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends installing anti-virus software on your PC that can access the affected product, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-1284 Improper Validation of Specified Quantity in Input Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H Acknowledgments Mitsubishi Electric discovering this vulnerability Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2025-001 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2025-04-25 Date Revision Summary 2025-04-25 1 CISA Republication - Initial Republication 2025-04-25 2 Initial Publication 2025-10-09 3 RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, RJ71EN71, NZ2GACP610-60, and NZ2KT-NPETNG51 have been added as affected products and fixed products, and the "remediations" was revised. 2025-10-09 4 CISA Republication - Update A - Update to Affected products, Impact, Countermeasures for Customers, Countermeasures for Products have been revised. The affected products RJ71GN11-T2, RJ71GN11-EIP, RJ71GN11-SX, RJ71EN71, NZ2GACP610-60 and NZ2KT-NPETNG51 have been added. 2026-02-03 5 CISA Republication - Update B - Update to Summary, Affected products, and Remediations have been revised. The affected products FX5-CCLGN-MS, FX5-ENET, and FX5-ENET/IP have been added. 2026-02-03 6 FX5-CCLGN-MS, AFX5-ENET, and AFX5-ENET/IP have been added as affected products and fixed products, and the "remediations" was revised. 2026-04-23 7 Added FX5-CCLGN-MS and FX5-ENET/IP have been added as fixed products, and the "remediations" was revised. 2026-04-30 8 CISA Republication - Update C - Added FX5-CCLGN-MS and FX5-ENET/IP that have been fixed to Countermeasures for Products. Affected products, Countermeasures for Customers, and Countermeasures for Products have been revised. 2026-08-27 9 R04ENCPU (Network Part), R08RNCPU (Network Part), R16ENCPU (Network Part), R32ENCPU (Network Part), and R12ENCPU (Network Part) have been added as affected products and fixed products, and the "remediations" was revised. 2026-08-27 10 CISA Republication update based on Mitsubishi Electric 2025-001 advisory Legal Notice and Terms of Use

Impact

Mitsubishi Electric CC-Link IE TSN Remote I/O modules (NZ2GN2S1-32D, NZ2GN2S1-32T, NZ2GN2S1-32TE, NZ2GN2S1-32DT, NZ2GN2S1-32DTE, NZ2GN2B1-32D, NZ2GN2B1-32T, NZ2GN2B1-32TE, NZ2GN2B1-32DT, NZ2GN2B1-32DTE, NZ2GNCF1-32D, NZ2GNCF1-32T, NZ2GNCE3-32D, NZ2GNCE3-32DT, NZ2GN12A4-16D, NZ2GN12A4-16DE, NZ2GN12A2-16T, NZ2GN12A2-16TE, NZ2GN12A42-16DT, NZ2GN12A42-16DTE, NZ2GN2S1-16D, NZ2GN2S1-16T, NZ2GN2S1-16TE, NZ2GN2B1-16D, NZ2GN2B1-16T, NZ2GN2B1-16TE), CC-Link IE TSN Analog-Digital Converter modules, Digital-Analog Converter modules, FPGA modules, MELSEC iQ-R Series CPU modules (R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, R120ENCPU), and MELSEC iQ-F Series modules.

Exploitation Status

No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.

Timeline

Newly disclosed

Remediation

Users should apply patches or updates provided by Mitsubishi Electric for the affected products. Specific patch numbers or versions were not mentioned, so checking with the vendor for the latest security updates is recommended. Additionally, network configurations should be reviewed to limit exposure to UDP packets that could exploit this vulnerability.

Additional Information

This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.

Related Topics: This incident relates to CVE, Vulnerability, Update, and 1 more.

Related Coverage

Palo Alto Networks warns of PAN-OS RCE flaw exploited in attacks

BleepingComputer

Palo Alto Networks has identified a serious vulnerability in its PAN-OS, labeled CVE-2026-0322, which allows for remote code execution (RCE). This flaw is particularly concerning as it has already been exploited in attacks focusing on their firewall products. Users of Palo Alto's firewalls are at risk, as attackers can potentially gain unauthorized access and control over affected systems. To address this issue, Palo Alto Networks has issued security updates, urging users to apply them promptly to safeguard their networks. This incident highlights the ongoing challenges organizations face in securing their infrastructure against emerging cyber threats.

Oct 14, 2026

Anthropic 'SneakPeek' Flaw Is a Silent Zero-Click Threat

darkreading

A vulnerability has been discovered in the preview pane of Claude Code Desktop, which could allow attackers to steal sensitive credentials from developers without any interaction required. This zero-click flaw poses a significant risk as it can extract SSH private keys, AWS credentials, and Claude OAuth tokens quietly. Developers using this software may unknowingly expose their credentials, leading to potential unauthorized access to their systems and services. This incident raises concerns about the security of development tools and the need for heightened vigilance among users. It's crucial for developers to stay informed about this vulnerability and take necessary precautions to protect their sensitive information.

Oct 14, 2026

FBI raids DPRK IT worker laptop farms in Texas, US nationals arrested

BleepingComputer

The U.S. Department of Justice has taken significant action against the Famous Chollima group, which is linked to North Korean IT workers allegedly engaged in remote schemes. Two individuals were arrested, and 14 others have been charged, with authorities seizing nearly 187 laptops that were reportedly used in these operations. This crackdown is part of broader efforts to combat North Korean cyber activities that threaten U.S. interests and the global cybersecurity landscape. The operation underscores the ongoing challenges posed by state-sponsored cyber activities and the need for vigilance in monitoring such threats. The arrests and seizures may disrupt the group's operations and deter similar activities in the future.

Oct 14, 2026

Ledger asks sellers across Asia to halt sales after supply-chain attack

BleepingComputer

Ledger, a well-known cryptocurrency wallet manufacturer, has initiated a halt on sales of its devices across several Asian countries, including Indonesia, Singapore, Thailand, the Philippines, Vietnam, Malaysia, and Hong Kong. This decision comes amid concerns about potential tampering with the devices in the supply chain. Ledger has reached out to resellers and distributors, urging them to remove affected products from their shelves while the company conducts a thorough investigation. This situation raises significant concerns for users who rely on these wallets for secure cryptocurrency storage, as compromised devices could lead to unauthorized access to their funds. The company’s proactive approach aims to ensure the integrity of its products and protect its customers from possible security risks.

Oct 14, 2026

Cisco patches new Secure Email Gateway zero-day exploited in attacks

BleepingComputer

Cisco has issued a critical patch for a zero-day vulnerability in its Secure Email Gateway (SEG) that has been actively exploited by attackers. This flaw allows remote, unauthenticated users to execute commands with root privileges, posing a significant risk to organizations using the affected software. The vulnerability is particularly concerning as it can lead to unauthorized access and control over email systems, potentially compromising sensitive data. Users of Cisco's SEG are urged to apply the available patches immediately to safeguard their systems against these attacks. The situation emphasizes the need for timely updates and vigilance in protecting email infrastructures from evolving threats.

Oct 14, 2026

U.S. Shuts Down Over 40 Laptop Farms, Charges 14 in North Korean IT Worker Fraud

The Hacker News

The U.S. Department of Justice has charged 14 individuals and seized around 187 computers in a crackdown on a North Korean scheme that involved fraudulent remote IT workers. This operation targeted a conspiracy that impacted over 70 U.S. companies, with the accused facing charges related to wire fraud. The defendants include both U.S. citizens and Chinese nationals, highlighting the international dimension of the fraud. By disrupting this scheme, the U.S. aims to prevent North Korea from generating revenue through illegal means, which could potentially support its nuclear weapons program. This case underscores the ongoing challenges posed by state-sponsored cybercrime and the importance of international cooperation in addressing such threats.

Oct 14, 2026