Inductive Automation Ignition
Overview
Inductive Automation's Ignition platform has a serious vulnerability that allows any authenticated user to create projects, due to a misconfigured setting in versions 8.1.53 and earlier. This is classified as CVE-2026-77393 and has a CVSS score of 8.8, indicating a high-level risk. The issue stems from the 'Create Project Role(s)' setting being left blank, which means no role restrictions were enforced. Users are encouraged to upgrade to version 8.1.54 or later, where project creation is limited to Designer sessions, or to configure their current version to restrict project creation appropriately. This vulnerability poses risks in critical sectors such as manufacturing and energy, making it crucial for organizations using this software to address the issue promptly to prevent unauthorized project creation.
Key Takeaways
- Affected Systems: Inductive Automation Ignition versions 8.1.53 and earlier; CVE-2026-77393.
- Action Required: Upgrade to Inductive Automation Ignition version 8.
- Timeline: Newly disclosed
Original Article Summary
View CSAF Summary Successful exploitation of this vulnerability could allow any authenticated user to create projects. The following versions of Inductive Automation Ignition are affected: Ignition <=8.1.53 (CVE-2026-77393) CVSS Vendor Equipment Vulnerabilities v3 8.8 Inductive Automation Inductive Automation Ignition Incorrect Default Permissions Background Critical Infrastructure Sectors: Critical Manufacturing, Energy, Information Technology Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-77393 In Ignition 8.1.53 and earlier, the Gateway "Create Project Role(s)" setting shipped blank, which permitted any authenticated user to create projects (if they can execute gateway scripts). Ignition 8.1.54 restricts project creation to Designer sessions and no longer relies on this setting. The 8.3 series is not affected. View CVE Details Affected Products Inductive Automation Ignition Vendor: Inductive Automation Product Version: Inductive Automation Ignition: <=8.1.53 Product Status: known_affected Remediations Mitigation Inductive Automation has determined that this issue is a default-value configuration, not a flaw in the access control itself. The security control enforces exactly what the "Create Project Role(s)" setting specifies; because the setting shipped blank, no role was required to create a project. Populating the setting fully closes the vulnerability. Mitigation Inductive Automation recommends users upgrade to 8.1.54 or later (or the latest 8.3 version), which restricts project creation to Designer sessions and no longer relies on this setting. Users who must remain on an earlier 8.1 version can fully remediate the issue by setting "Create Project Role(s)" to match their Designer Role. Once the setting is populated, only users holding that role can create projects. See Gateway General Security Settings. https://docs.inductiveautomation.com/docs/8.1/platform/security/gateway-general-security-settings#gateway-security-settings-table Mitigation For more information, see the publication at the Inductive Automation Trust Center. https://security.inductiveautomation.com/?tcuUid=34477620-731d-4b70-b22b-9450f9a659a3 Relevant CWE: CWE-276 Incorrect Default Permissions Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N Acknowledgments Christopher Lusk of North Echo Security Research reported this vulnerability to Inductive Automation. Elhussain Fathy (0xSphinx) independently reported this vulnerability and confirmed the fix. Inductive Automation reported this vulnerability to CISA. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. Revision History Initial Release Date: 2026-09-03 Date Revision Summary 2026-09-03 1 Initial Republication of Inductive Automation Trust Center update. Legal Notice and Terms of Use
Impact
Inductive Automation Ignition versions 8.1.53 and earlier; CVE-2026-77393.
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Newly disclosed
Remediation
Upgrade to Inductive Automation Ignition version 8.1.54 or later. Alternatively, for users remaining on earlier versions, set the 'Create Project Role(s)' to match the Designer Role to restrict project creation access.
Additional Information
This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.
Related Topics: This incident relates to Phishing, CVE, Vulnerability, and 2 more.