Mitsubishi Electric GX Works3 and Motion Control Settings
Overview
A vulnerability has been discovered in Mitsubishi Electric's GX Works3 and Motion Control Settings software that could allow local attackers to bypass authentication even with an invalid password. This flaw, identified as CVE-2026-15688, affects all versions of these products. Attackers could exploit this weakness to access, modify, or delete control programs, posing a significant risk to critical manufacturing operations globally. Mitsubishi Electric recommends users update to specific software versions to mitigate the risk and implement several security measures, including restricting network access and using firewalls. This incident emphasizes the need for robust cybersecurity practices in industrial control systems.
Key Takeaways
- Affected Systems: Affected products include Mitsubishi Electric GX Works3 (all versions) and Mitsubishi Electric Motion Control Settings (all versions).
- Action Required: Customers should download and install GX Works3 version 1.
- Timeline: Disclosed on October 2023
Original Article Summary
View CSAF Summary Successful exploitation of this vulnerability could allow a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. The following versions of Mitsubishi Electric GX Works3 and Motion Control Settings are affected: Mitsubishi Electric GX Works3 vers:all/* (CVE-2026-15688) Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3) vers:all/* (CVE-2026-15688) CVSS Vendor Equipment Vulnerabilities v3 8.8 Mitsubishi Electric Mitsubishi Electric GX Works3 and Motion Control Settings Incorrect Implementation of Authentication Algorithm Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Japan Vulnerabilities Expand All + CVE-2026-15688 Incorrect Implementation of Authentication Algorithm (CWE-303) vulnerability in the affected products allows a local attacker to successfully authenticate even with an invalid block password by executing the affected product and modify part of the executable module in memory, and thereby allows the attacker to view, tamper with, destroy, or delete control programs. View CVE Details Affected Products Mitsubishi Electric GX Works3 and Motion Control Settings Vendor: Mitsubishi Electric Product Version: Mitsubishi Electric GX Works3: vers:all/*, Mitsubishi Electric Motion Control Settings (Software packaged with GX Works3): vers:all/* Product Status: known_affected Remediations Workaround For customers using GX Works3, please download version 1.096A or later from the link https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/plceng&shiryoid=1000001411&lang=2&select=0&softid=1&infostatus=1_2_1&viewradio=0&viewstatus=&viewpos=, install it, and set the security version for projects to "2". Please refer to “15.9 Preventing Illegal Access to/Falsification of Data (Security Version)” in “GX Works3 Operating Manual” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory available at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf". Workaround For customers using Motion Control Settings (Software packaged with GX Works3), Please download version 1.070Y or later from the link "https://www.mitsubishielectric.com/fa/download/software/detailsearch.page?mode=software&kisyu=/ssc&shiryoid=1000000803&lang=2&select=0&softid=1&infostatus=1_8_1&viewradio=0&viewstatus=&viewpos=", install it, and set the security version for projects to "2". Please refer to “12.5 Preventing Illegal Access to/Falsification of Data (Security Version)” in “Motion Control Setting Function Help” for details. For more information about the workaround, refer to the Mitsubishi Electric security advisory at "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-007_en.pdf". Mitigation For customers of the affected products, Mitsubishi Electric recommends using a computer with the affected product within a LAN and blocking remote logins from untrusted networks, hosts, and users, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends using a firewall, virtual private network (VPN), etc., to prevent unauthorized access, and allowing remote login only to trusted users when connecting a computer with the affected product to the Internet, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends preventing the user from clicking on web links contained in emails or other messages from untrusted sources, or from opening attachments in untrusted emails, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends installing antivirus software on a computer running the affected product, to minimize the risk of exploiting this vulnerability. Mitigation For customers of the affected products, Mitsubishi Electric recommends restricting physical access to a computer on which the affected product is installed, as well as to computers and network devices that can communicate with it, to minimize the risk of exploiting this vulnerability. Relevant CWE: CWE-303 Incorrect Implementation of Authentication Algorithm Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H 4.0 9.2 CRITICAL CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:N/SC:N/SI:H/SA:H Acknowledgments Mayeul Fargier, Erwan Cordier, Noé Flatreaud reported this vulnerability to Mitsubishi Electric. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Mitsubishi Electric 2026-007 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Mitsubishi Electric directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-09-17 Date Revision Summary 2026-09-17 1 Initial Publication 2026-09-17 2 Initial CISA Republication of Mitsubishi Electric 2026-007 advisory Legal Notice and Terms of Use
Impact
Affected products include Mitsubishi Electric GX Works3 (all versions) and Mitsubishi Electric Motion Control Settings (all versions).
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Disclosed on October 2023
Remediation
Customers should download and install GX Works3 version 1.096A or later and Motion Control Settings version 1.070Y or later. Additionally, users should set the security version for projects to '2'. Recommended mitigations include using a LAN for affected products, blocking remote logins from untrusted networks, employing firewalls and VPNs, and restricting physical access to devices.