Siemens Capital Embedded AR Classic
Overview
Siemens has identified an out-of-bounds read vulnerability (CVE-2026-89208) in its Capital Embedded AR Classic products that could allow attackers to read memory outside of intended boundaries. This vulnerability affects the Capital Embedded AR Classic versions 431-422 and R20-11 prior to version 2303, potentially leading to abnormal behavior or denial of service. Siemens has released an updated version for R20-11 and is working on further fixes for the affected products. They recommend users implement network segmentation and ensure that devices are protected by firewalls to mitigate risks until a patch is available. This issue is significant because it affects critical infrastructure sectors, including manufacturing, transportation, and healthcare, putting essential services at risk.
Key Takeaways
- Affected Systems: Affected products include Capital Embedded AR Classic 431-422 (all versions) and Capital Embedded AR Classic R20-11 (versions intdot/<2303). Vendor: Siemens.
- Action Required: Users should update to Capital Embedded AR Classic R20-11 version 2303 or later.
- Timeline: Disclosed on October 13, 2026
Original Article Summary
View CSAF Summary The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. The following versions of Siemens Capital Embedded AR Classic are affected: Capital Embedded AR Classic 431-422 vers:all/* (CVE-2026-89208) Capital Embedded AR Classic R20-11 vers:intdot/<2303 (CVE-2026-89208) CVSS Vendor Equipment v3 5.3 Siemens Capital Embedded AR Classic 431-422 1 Vulnerability Out-of-bounds Read Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-89208 The affected product does not properly validate input bounds before accessing packet data. This could allow an unauthenticated remote attacker to trigger memory reads outside the intended packet boundaries. Read More 2 Affected Products Capital Embedded AR Classic 431-422 Product Status: known_affected Remediations Mitigation Apply network segmentation and put the ECUs behind properly configured gateways/firewalls No fix planned Currently no fix is planned Capital Embedded AR Classic R20-11 < V2303 Product Status: known_affected Remediations Mitigation Apply network segmentation and put the ECUs behind properly configured gateways/firewalls Vendor fix Update to V2303 or later version Additional Metrics Relevant CWE: CWE-125 Out-of-bounds Read CVSS Version Base Score Base Severity Vector String 3.1 5.3 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-055299 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-10-13 Date Revision Summary 2026-10-13 1 Publication Date 2026-10-22 2 Initial CISA Republication of Siemens ProductCERT SSA-055299 advisory Legal Notice and Terms of Use
Impact
Affected products include Capital Embedded AR Classic 431-422 (all versions) and Capital Embedded AR Classic R20-11 (versions intdot/<2303). Vendor: Siemens.
Exploitation Status
No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.
Timeline
Disclosed on October 13, 2026
Remediation
Users should update to Capital Embedded AR Classic R20-11 version 2303 or later. For affected products without a fix, Siemens recommends applying network segmentation and placing the ECUs behind properly configured gateways/firewalls.