Critical

Siemens Industrial Edge Devices

All CISA Advisories

Overview

Siemens has identified multiple path traversal vulnerabilities in its Industrial Edge Devices that could allow authenticated remote attackers to access sensitive internal information. The affected products include various versions of the Industrial Edge Cloud Device, Industrial Edge Own Device, Industrial Edge Virtual Device, and multiple models of the SCALANCE and SIMATIC HMI panels. Siemens has released updated versions for several of these devices and strongly advises users to apply these updates. For products that do not yet have fixes available, the company is working on further remedies and recommends implementing specific mitigations to enhance security. Given the nature of these vulnerabilities, it is crucial for organizations using these devices to take immediate action to protect their systems from potential exploitation.

Key Takeaways

  • Affected Systems: Affected products include: Industrial Edge Cloud Device (IECD) versions <1.28.1, Industrial Edge Own Device (IEOD) versions <1.28.1, Industrial Edge Virtual Device (IEVD) versions <1.28.1, SCALANCE LPE9413 and LPE9433 (all versions), and various SIMATIC HMI MTP1000, MTP1200, MTP1500, MTP1900, MTP2200, and MTP700 models (all versions).
  • Action Required: Siemens recommends updating to the latest versions of the affected products, specifically versions 1.
  • Timeline: Newly disclosed

Original Article Summary

View CSAF Summary Siemens Industrial Edge Devices contain multiple path traversal vulnerabilities that could facilitate an authenticated remote attacker to access sensitive internal information. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens Industrial Edge Devices are affected: Industrial Edge Cloud Device (IECD) vers:intdot/<1.28.1 (CVE-2026-44414) Industrial Edge Own Device (IEOD) vers:intdot/<1.28.1 (CVE-2026-44414) Industrial Edge Virtual Device (IEVD) vers:intdot/<1.28.1 (CVE-2026-44414) SCALANCE LPE9413 (6GK5998-3GS01-2AC2) vers:all/* (CVE-2026-44414) SCALANCE LPE9433 (6GK5998-3GS11-2AC2) vers:all/* (CVE-2026-44414) SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3MB57-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3QB57-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3UB57-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3XB57-0BX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP700 Unified Comfort Panel (6AV2128-3GB06-0AX1) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0) vers:all/* (CVE-2026-44415) SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1) vers:all/* (CVE-2026-44415) SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2) vers:intdot/<1.28.1.2 (CVE-2026-44414) SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2) vers:intdot/<1.28.1.2 (CVE-2026-44414) SIMATIC IPC BX-21A Industrial Edge Device vers:intdot/<1.28.1.2 (CVE-2026-44414) SIMATIC IPC BX-39A Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC BX-59A Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC127E Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC227E Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC227G Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC427E Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIMATIC IPC847E Industrial Edge Device vers:intdot/<3.2.0.17 (CVE-2026-44414) SIPLUS HMI MTP1000 Unified Comfort (6AG1128-3KB06-4AX1) vers:all/* (CVE-2026-44415) SIPLUS HMI MTP1200 Unified Comfort (6AG1128-3MB06-4AX1) vers:all/* (CVE-2026-44415) SIPLUS HMI MTP700 Unified Comfort (6AG1128-3GB06-4AX1) vers:all/* (CVE-2026-44415) CVSS Vendor Equipment v3 9.1 Siemens Industrial Edge Cloud Device (IECD) 1 Vulnerability Path Traversal: '.../...//' Background Critical Infrastructure Sectors: Critical Manufacturing, Transportation Systems, Energy, Healthcare and Public Health, Financial Services, Government Services and Facilities Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-44414 Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system. Read More 15 Affected Products Industrial Edge Cloud Device (IECD) < V1.28.1 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1 or later version Industrial Edge Own Device (IEOD) < V1.28.1 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1 or later version Industrial Edge Virtual Device (IEVD) < V1.28.1 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1 or later version SCALANCE LPE9413 (6GK5998-3GS01-2AC2) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SCALANCE LPE9433 (6GK5998-3GS11-2AC2) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2) < V1.28.1-2 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1-2 or later version SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2) < V1.28.1-2 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1-2 or later version SIMATIC IPC BX-21A Industrial Edge Device < V1.28.1-2 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V1.28.1-2 or later version SIMATIC IPC BX-39A Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC BX-59A Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC127E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC227E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC227G Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC427E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version SIMATIC IPC847E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only Vendor fix Update to V3.2.0-17 or later version Additional Metrics Relevant CWE: CWE-35 Path Traversal: '.../...//' CVSS Version Base Score Base Severity Vector String 3.1 6.8 MEDIUM CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N View CVE Details CVE-2026-44415 Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system or result in the deletion of data. Read More 66 Affected Products Industrial Edge Cloud Device (IECD) < V1.28.1 Product Status: known_affected Remediations Industrial Edge Own Device (IEOD) < V1.28.1 Product Status: known_affected Remediations Industrial Edge Virtual Device (IEVD) < V1.28.1 Product Status: known_affected Remediations SCALANCE LPE9413 (6GK5998-3GS01-2AC2) Product Status: known_affected Remediations SCALANCE LPE9433 (6GK5998-3GS11-2AC2) Product Status: known_affected Remediations SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2) < V1.28.1-2 Product Status: known_affected Remediations SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2) < V1.28.1-2 Product Status: known_affected Remediations SIMATIC IPC BX-21A Industrial Edge Device < V1.28.1-2 Product Status: known_affected Remediations SIMATIC IPC BX-39A Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC BX-59A Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC127E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC227E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC227G Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC427E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC IPC847E Industrial Edge Device < V3.2.0-17 Product Status: known_affected Remediations SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3MB27-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3MB27-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3MB27-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3MB57-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3MB57-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3MB57-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Unified Comfort Panel (6AV2128-3MB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Unified Comfort Panel hygienic (6AV2128-3MB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design (6AV2128-3MB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1200 Unified Comfort Panel neutral design (6AV2128-3MB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3QB27-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3QB27-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3QB27-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3QB57-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3QB57-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3QB57-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Unified Comfort Panel (6AV2128-3QB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Unified Comfort Panel hygienic (6AV2128-3QB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design (6AV2128-3QB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1500 Unified Comfort Panel neutral design (6AV2128-3QB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3UB27-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3UB27-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3UB27-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3UB57-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3UB57-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3UB57-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Unified Comfort Panel (6AV2128-3UB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Unified Comfort Panel hygienic (6AV2128-3UB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design (6AV2128-3UB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1900 Unified Comfort Panel neutral design (6AV2128-3UB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom) (6AV2128-3XB27-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit (6AV2128-3XB27-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top) (6AV2128-3XB27-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom) (6AV2128-3XB57-1BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extension (6AV2128-3XB57-0BX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top) (6AV2128-3XB57-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Unified Comfort Hygienic (6AV2128-3XB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design (6AV2128-3XB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Unified Comfort Panel (6AV2128-3XB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP2200 Unified Comfort Panel neutral design (6AV2128-3XB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP700 Unified Comfort Panel (6AV2128-3GB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design (6AV2128-3GB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP700, Unified Comfort Panel neutral design (6AV2128-3GB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1000 Unified Comfort Panel (6AV2128-3KB06-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIPLUS HMI MTP1000 Unified Comfort (6AG1128-3KB06-4AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIPLUS HMI MTP1200 Unified Comfort (6AG1128-3MB06-4AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIPLUS HMI MTP700 Unified Comfort (6AG1128-3GB06-4AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1000 Unified Comfort Panel hygienic (6AV2128-3KB40-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design (6AV2128-3KB70-0AX0) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available SIMATIC HMI MTP1000, Unified Comfort Panel neutral (6AV2128-3KB36-0AX1) Product Status: known_affected Remediations Mitigation Ensure network access to affected products is limited to trusted parties only None available Currently no fix is available Additional Metrics Relevant CWE: CWE-35 Path Traversal: '.../...//' CVSS Version Base Score Base Severity Vector String 3.1 9.1 CRITICAL CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported these vulnerabilities to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-832641 from a direct conversion of the vendor's Common Security Advisory Framework (CSAF) advisory. This is republished to CISA's website as a means of increasing visibility and is provided "as-is" for informational purposes only. CISA is not responsible for the editorial or technical accuracy of republished advisories and provides no warranties of any kind regarding any information contained within this advisory. Further, CISA does not endorse any commercial product or service. Please contact Siemens ProductCERT directly for any questions regarding this advisory. Revision History Initial Release Date: 2026-10-13 Date Revision Summary 2026-10-13 1 Publication Date 2026-10-22 2 Initial CISA Republication of Siemens ProductCERT SSA-832641 advisory Legal Notice and Terms of Use

Impact

Affected products include: Industrial Edge Cloud Device (IECD) versions <1.28.1, Industrial Edge Own Device (IEOD) versions <1.28.1, Industrial Edge Virtual Device (IEVD) versions <1.28.1, SCALANCE LPE9413 and LPE9433 (all versions), and various SIMATIC HMI MTP1000, MTP1200, MTP1500, MTP1900, MTP2200, and MTP700 models (all versions).

Exploitation Status

No active exploitation has been reported at this time. However, organizations should still apply patches promptly as proof-of-concept code may exist.

Timeline

Newly disclosed

Remediation

Siemens recommends updating to the latest versions of the affected products, specifically versions 1.28.1 or later for IECD, IEOD, and IEVD. For SCALANCE LPE9413 and LPE9433, and SIMATIC HMI devices, users should also seek the latest updates as they become available. In cases where fixes are not yet implemented, Siemens suggests following specific mitigations provided for those products.

Additional Information

This threat intelligence is aggregated from trusted cybersecurity sources. For the most up-to-date information, technical details, and official vendor guidance, please refer to the original article linked below.

Related Topics: This incident relates to CVE, Vulnerability, Update, and 1 more.

Related Coverage

College Board confirms data breach after unauthorized password changes

BleepingComputer

The College Board has confirmed a data breach after students noticed unauthorized changes to their passwords on Thanksgiving. According to the organization, attackers accessed its account registration and financial aid application systems, raising concerns about the security of sensitive student information. This incident affects many students who rely on the College Board for college admissions and financial aid processes. With personal data potentially compromised, the breach highlights the vulnerabilities that educational organizations face in protecting user information. The College Board is likely to face scrutiny regarding its security measures and how it plans to prevent future incidents.

Nov 28, 2026

pCloud Password Manager Hit by Cyber Attack Involving Email Address Exposure and Login Attempts

The Hacker News

pCloud Pass, a cross-platform password manager, confirmed it experienced a cyber attack that led to unauthorized login attempts on some user accounts. Users began reporting unusual device connections to their accounts, prompting the company to investigate. pCloud stated that the attack was swiftly contained, but a limited number of user email addresses were exposed during the incident. This breach raises concerns about the security of password managers, which are designed to protect sensitive login information. Users of pCloud Pass should monitor their accounts closely and consider changing their passwords to enhance security.

Nov 28, 2026

Unpatched Cacti zero-day with public PoC gives remote code execution

BleepingComputer

A recently discovered zero-day vulnerability in the Cacti network monitoring software allows unauthenticated attackers to remotely execute commands on affected servers. This flaw has been made public, along with a proof-of-concept exploit, which means that it is now easier for malicious actors to take advantage of the weakness. Organizations using Cacti need to be particularly vigilant, as this vulnerability poses a significant risk to their network security. The incident underscores the necessity for timely patching and monitoring of network systems to guard against potential exploitation. Users should prioritize updating their Cacti installations as soon as possible to mitigate this risk.

Nov 27, 2026

US Air Force cloud platform reportedly hacked in latest federal breach

BleepingComputer

The US Air Force's Cloud One computing platform has been compromised by hackers, adding to a troubling trend of cyberattacks against various US government agencies, including the FBI, CIA, and Treasury Department. This breach raises significant concerns about the security of federal systems, particularly as they hold sensitive data and are critical to national defense operations. The incident reflects a broader vulnerability within government networks, suggesting that attackers are increasingly targeting these systems. As investigations continue, the Air Force and other agencies will likely need to reassess their cybersecurity measures to prevent further incidents. The implications of such breaches can be severe, potentially compromising national security and public trust.

Nov 27, 2026

Your Firewall Isn't Enough: The Hidden Risk of Unmanaged VMs

BleepingComputer

The article discusses the security risks posed by unmanaged virtual machines (VMs) within IT infrastructures. Forgotten or unpatched VMs can create significant vulnerabilities, as they may not receive necessary updates or may have excessive access permissions. This situation can lead to security blind spots, making it easier for attackers to exploit weaknesses. The piece emphasizes the importance of centralized infrastructure management, implementing strict access controls, and automating resource lifecycle management as effective strategies to mitigate these risks. Companies need to be proactive in managing their VMs to safeguard their systems and data.

Nov 27, 2026

'God Mode' Flaws Could Wreak Border-Control Havoc

darkreading

Recent research has revealed vulnerabilities in the online visa and immigration systems of several countries, including Nigeria, Ethiopia, Zambia, Sri Lanka, Fiji, and Ghana. These flaws, dubbed 'God Mode', could allow attackers to disrupt the entry of travelers into these nations. This presents a significant risk, as it could hinder border control operations and create chaos for individuals attempting to enter these countries. The potential for exploitation raises concerns about national security and the integrity of immigration processes. As countries increasingly rely on digital systems for border management, addressing these vulnerabilities is crucial to prevent potential disruptions.

Nov 27, 2026